[ English | Bahasa Malaysia ] Hari ini ialah 2 Dec 2024, 03:43 PM (Terakhir dikemaskini pada: 2nd Dec 2024)

Text Red Text Black Text Blue Text Green Text Smaller Text Reset Text Larger

Publication Details
Year :

2012

Journal :

Mohammed Morish, Yasmin Ayob, Noris Naim, Huda Salman, Nor Asiah Muhamad and Narazah Mohd Yusoff (2012). Quality indicator for discarding blood in the National Blood Center, Kuala Lumpur. Asian Journal of Transfusion Medicine 6(1): 19-23

Abstract :

Background and Objective: The implementation of quality system and continuous evaluation of all activities of the Blood Transfusion Services (BTS) can help to achieve the maximum quantity and quality of safe blood. Optimizing blood collection and processing would reduce the rate of discard and improve the efficiency of the BTS. The objective of this study is to determine the rate of discard of blood and blood component and identify its reasons at the National Blood Centre (NBC), Kuala Lumpur, during the year of 2007 in order to introduce appropriate intervention.

 

Study Designs and Methods: Data on the number of discarded whole blood units and its components, reasons for discard, and the number of blood components processed as well as the number of collected blood units were obtained from the Blood Bank Information System - NBC database. These were analyzed.

 

Results: The total number of blood units collected in 2007 was 171169 from which 390636 units of components were prepared. The total number of discarded whole blood units and its components was 8968 (2.3%). Platelet concentrate recorded the highest of discard at 6% (3909) followed by whole blood at 3.7% (647), fresh frozen plasma (FFP) at 2.5% (2839), and cryoprecipitate at 2% (620). The rate of discarded packed red blood cells RBCs, plasma aphaeresis, and PLT aphaeresis was less than 1% at 0.6% (902), 0.6% (37), and 0.29% (14), respectively. RBC contamination of PLT and plasma were the major cause of discard at 40% (3558). Other causes include leakage (26% - 2306), lipemia (25% - 2208), and underweight (4% - 353).

 

Conclusion: Good donor selection, training and evaluation of the staff, as well as implementation of automation will help to improve processes and output of BTS. This would reduce discard of blood components and wastage caused by non conformance.

myGOV MAMPU JPA IKU MSC NMMR CRC MyHEALTH MOH Globinmed SPA krste.my

Notis

 

Laman ini sesuai dilihat menggunakan Firefox (24.0) dengan resolusi 1280 x 768 pixels atau lebih.

Lokasi Kami

world

Kami terletak di Setia Alam, Selangor, Malaysia. Klik pada imej peta untuk melancarkan servis Google Maps.

Hubungi Kami